I'm having some trouble and wondering if I could get some guidance in this forum.
I'm just starting with a tape library system 124T LT06 (under warranty) and I'm getting errors. This has been racked for several months and just now firing it up. I'm using the web interface (and ITDT) and running some tests since my tape application wasn't seeming to do all that well.
Tape Alerts: | Flags[1-64]:0000000200000000 TA[31]-HardwareB |
operator control panel shows (and did this after I power cycled it)
LCD: | Drive TAflag[31] HardwareB |
error log looks like that:
Hard Queue: Drive Reported a Hardware Error Type (3B) POC:00005 POH:03576:25:58 #000 Drive Load Error Type (3E) POC:00006 POH:00003:19:06 #001 Drive Load Error Type (3E) POC:00006 POH:00072:07:23 #002
-
the drive is version d8e3.
autoloader v90.0 (005a.0h)
I installed the IBM Tape Diagnostic Tool Standard Edition on a 2012R2 SAS attached system and
ran install_itdt_se_WindowsX86_64_9.0.0.20150609.
When running device test screen it gets FAILED EC 5.
Here's the output from a random move test
Test Name: Random Move Test *Stopped* Test Start Time: POC:00007 POH:00004:28:04 Test End Time: POC:00007 POH:00004:37:50 Last Sequence: Random Move Count: 1 Last Status: Test Failed - Drive Reported a Hardware Error (0x3B) ---Random Stats--- Moves 0 Loads 0 Cycles 0 Recals 0 Inventories 1 Mismatch 0 BarCodeErrs 0 (Initial 0)(Test Start # 0), Skips 0, HW 0 BarCodeNoRdErrs 0 (0 - 0)(Current Total - Test Start Total) Max Move Time 0.0 sec Min Move Time 4294967.295 sec Avg Move Time 0.0 sec Seed 17721 RETRY INFO LMAG RMAG TRAN/DRV ROT/LD/UN ELEV Count(Limit) Count(Limit) Count(Limit) Count(Limit) Count(Limit) ---------- ------------ ------------ ------------ ------------ ------------ Operational: 0( 3) 0( 3) 0( 2) 0( 1) 0( 1) Total Mtr: 0(-1) 0(-1) 0(-1) 0(-1) 0(-1) Total Mtr/100: 0(10) 0(10) 0(20) 0(30) 0(10) Mtr/100: 0( 5) 0( 5) 0(10) 0( 5) 0( 5) Error/100: 0( 5) 0( 5) 0(10) 0( 5) 0( 5) Pos Err/100: 0( 5) 0( 5) 0(10) 0( 5) 0( 5) ScanErr per Elem (err/attempt) L: 0/5 | 0/0 | 0/0 | 0/0 | 0/5 | 0/0 | 0/0 | 0/0 | R: 0/5 | 0/0 | 0/0 | 0/4 | 0/0 | 0/0 | 0/0 | 0/0 | Drive: 0/0 Temperatures (Celsius) - Tape Drive:N/A Picker:28 POH: 0004:38:11, Test Time:0000:09:46
Here's the view logs again after that last RANDOM test:
Hard Queue: Drive Reported a Hardware Error Type (3B) POC:00005 POH:03576:25:58 #000 Drive Load Error Type (3E) POC:00006 POH:00003:19:06 #001 Drive Load Error Type (3E) POC:00006 POH:00072:07:23 #002 Drive Reported a Hardware Error Type (3B) POC:00007 POH:00004:33:25 #003
So I'd be pleased for some guidance in this matter.
Thanks.
John