Quantcast
Channel: PowerVault Storage Forum - Recent Threads
Viewing all articles
Browse latest Browse all 1687

powervault 124T LTO6 setup with woe

$
0
0

I'm having some trouble and wondering if I could get some guidance in this forum.

I'm just starting with a tape library system 124T LT06 (under warranty) and I'm getting errors. This has been racked for several months and just now firing it up.  I'm using the web interface (and ITDT) and running some tests since my tape application wasn't seeming to do all that well.

Tape Alerts:Flags[1-64]:0000000200000000
TA[31]-HardwareB

operator control panel shows (and did this after I power cycled it)

LCD:Drive TAflag[31]
HardwareB

error log looks like that:

Hard Queue:

Drive Reported
a Hardware Error

Type (3B)
POC:00005
POH:03576:25:58 #000

Drive Load Error
Type (3E)
POC:00006
POH:00003:19:06 #001

Drive Load Error
Type (3E)
POC:00006
POH:00072:07:23 #002

-
the drive is version d8e3.
autoloader v90.0 (005a.0h)

I installed the IBM Tape Diagnostic Tool Standard Edition on a 2012R2 SAS attached system and
ran install_itdt_se_WindowsX86_64_9.0.0.20150609.
When running device test screen it gets FAILED EC 5.

Here's the output from a random move test
Test Name: Random Move Test *Stopped*
Test Start Time: POC:00007 POH:00004:28:04 
Test End Time: POC:00007 POH:00004:37:50 
Last Sequence: Random Move 
Count: 1 
Last Status: Test Failed - Drive Reported
a Hardware Error
 (0x3B)
---Random Stats---
Moves       0
Loads       0
Cycles      0
Recals      0
Inventories 1
Mismatch    0
BarCodeErrs     0 (Initial 0)(Test Start # 0), Skips 0, HW 0
BarCodeNoRdErrs 0 (0 - 0)(Current Total - Test Start Total)
Max Move Time 0.0 sec
Min Move Time 4294967.295 sec
Avg Move Time 0.0 sec
Seed 17721

RETRY INFO             LMAG         RMAG     TRAN/DRV    ROT/LD/UN         ELEV
               Count(Limit) Count(Limit) Count(Limit) Count(Limit) Count(Limit)
----------     ------------ ------------ ------------ ------------ ------------
Operational:          0( 3)        0( 3)        0( 2)        0( 1)        0( 1)
Total Mtr:            0(-1)        0(-1)        0(-1)        0(-1)        0(-1)
Total Mtr/100:        0(10)        0(10)        0(20)        0(30)        0(10)
Mtr/100:              0( 5)        0( 5)        0(10)        0( 5)        0( 5)
Error/100:            0( 5)        0( 5)        0(10)        0( 5)        0( 5)
Pos Err/100:          0( 5)        0( 5)        0(10)        0( 5)        0( 5)

ScanErr per Elem (err/attempt)
L:  0/5  |   0/0  |   0/0  |   0/0  |   0/5  |   0/0  |   0/0  |   0/0  | 
R:  0/5  |   0/0  |   0/0  |   0/4  |   0/0  |   0/0  |   0/0  |   0/0  | 
Drive:   0/0  
Temperatures (Celsius) - Tape Drive:N/A Picker:28
POH: 0004:38:11, Test Time:0000:09:46

Here's the view logs again after that last RANDOM test:
Hard Queue:

Drive Reported
a Hardware Error

Type (3B)
POC:00005
POH:03576:25:58 #000

Drive Load Error
Type (3E)
POC:00006
POH:00003:19:06 #001

Drive Load Error
Type (3E)
POC:00006
POH:00072:07:23 #002

Drive Reported
a Hardware Error

Type (3B)
POC:00007
POH:00004:33:25 #003

So I'd be pleased for some guidance in this matter.

Thanks.
John